FAQ Home FAQ

Common Faults and exclusion method of drilling rig

2010-02-06    Source:BOSUN TOOLS

Common Faults and exclusion method of drilling rig
Motor does not turn
Reason:Power unreasonable, or joint loosening
Remedy:

Reason :restore power, check all connectors and tighten
Remedy:

Reason:Action is not reset after the overcurrent protection device
Remedy:Press the reset button to restart the motor

Reason:Over-current protection device is damaged
Remedy:Replacement of over-current protection device

Slow drilling
Reason:Drill the end of life
Remedy:Replaced with new drill bits

Reason:Drill feed pressure is too low
Remedy:Increase the feed pressure

Reason:Drill Segment surface is fine crumb paste to live
Remedy:Cleaning drill, increase water pressure

Reason: skid result in Cut into thick steel
Remedy:Feed pressure decreases, and then increase the pressure to be reinforced through

Reason:Processing chip plot in thehole
Remedy:Clean-up the hole-bottom and inflating

Reason:Flow not smooth,Leakage or non-return
Remedy:Check water inlet valve, check the flow

Reason:Sharpness bit lower
Remedy:Use bricks or grinding wheel to re-open edge
Bit stuck:

Reason:Block of reinforcement metal or debris stuck in the drill core and drill bit and hole wall or between the between the.
Remedy:Stop the machine, using wrench turning left and right bit, or pull out the drill bit crack coring

Reason:Rack is not strong, resulting in displacement of
Remedy:Re-fixed the Rack

Reason:Rack column and sleeve gap is too large
Remedy:Adjust the sleeve gap
 
Drill wall wear too fast
Reason:Drill spindle is not core
Remedy:Repair or replacement of spindle

Reason:the bit errors
Remedy:Replacement the Bits

Reason:reinforcement metal or thin debris can not be discharged outside the hole
Remedy:To improve the water flow, remove the drill bit, clean the hole
 
Water jacket leaking
Reason:Skeleton ring wear or aging
Remedy:Replacement the rubber seal ring
 

 

TAG:None

RSS:RSS订阅